rev description date/appd a drawing under change control 9/17/04 gec impact assessment required prior to change drawn date j. levrault 11/12/2002 standard part - thr-5/3000-15/500-d12 checked date special part - input over voltage shutdown disabled d. deros a 9/15/2004 marketing date b. smith 9/3/2004 qa date t. brown 9/14/2004 mfg. date product specification d. paille 9/3/2004 THR-30185 proj. eng. date size code ident. no. dwg. no. rev m. zelfand 9/7/2004 a 50721 43869 a a ppd date e. wilcox 9/3/2004 sheet 1 of 4 ? ?
model: THR-30185 dc-dc converter product specifications 9/7/2004 input: min. typ. max. units test voltage range: 9.00 24.00 36.00 v 100% filter type: l-type gbd back ripple current: tbd ma gbd no load current @24vin: 25 75 ma 100% full load current @24vin: 874 974 ma 100% for typical loads efficiency at f. load @24vin: 80.0 81.0 % 100% overvoltage shutdown: na output: min. nom. max. total output power 2.70 17.000 17.85 w gbd for all possible combinations of output voltages and their loads for product test use nominal currents for each output unless specified voltage(1): 4.900 5.00 5.100 vdc 100% current range(1): 275.0 2,200 3,000 ma 100% voltage(2): 13.50 15.00 16.50 vdc 100% current range(2): 50.0 200.0 500.0 ma 100% voltage(3): -13.50 -15.00 -16.50 vdc 100% current range(3): -50.0 -200.0 -500.0 ma 100% voltage setting accuracy: within 2% of 5.00v % 100% measured at 24vin , 1.5a load line regulation at 5v: 2% slope( 1%) % 100% load regulation at 5v: 4% slope( 2%) % 100% load regulation at 12v: 10% slope( 5%) % 100% 20-100% load, 5v@ nominal load line regulation at 12v: 2% slope( 1%) % 100% measured at 5vo @ 2.75a, temperature coefficient @5v: 0.02 %/c gbd over-voltage protection @5v: na voltage clamp (transzorb) ripple/noise at 20 mhz bandwidth: 5v 50 85 mv pk/pk 100% 15v 75 150 mv pk/pk 100% (-)15v 75 150 mv pk/pk 100% dwg. no. 43869 rev. a sht 2 of 4
model: THR-30185 dc-dc converter product specifications 9/7/2004 current limit inception @5v: 3.50 3.70 4.10 a 100% at .985vout, 24v in, loads @ typical currents short circuit current @5v: 6 a 100% vo recovery test only, 24 vin dynamic load response recovery time @5v: 150 300 sec 100% 5v load switched from 1.35a to 2.7a,2% of vo general: min. typ. max. isolation voltage: 750 1000 vdc 100% isolation resistance: tbd mohm gbd isolation capacitance: 500 pf gbd switching frequency: 150 165 180 khz gbd sync-on/off control pin: provided, function tested meets requirements of: ul-1950 yes gbd csa-c22.2 no234 yes gbd vde n/a calculated mtbf: 200,000 hours gbd mechanical: min. typ. max. dimensions(nominal): 2" x 2" x .45" inches gbd weight (nominal): 2 ounces gbd 56 gram case material: baked enamel steel, gbd non conductive base emi/rfi shielding: five sided gbd environmental: min. typ. max. operating ambient temperature ta where no derating required: -25 55 c gbd natural convection,vertical mount. storage temperature -55 125 c gbd derating as per derating curve gbd dwg. no. 43869 rev. a sht 3 of 4
model: THR-30185 dc-dc converter product specifications 11/12/2002 dwg. no. 43869 rev. a sht 4 of 4 THR-30185 output power temperature derating curve 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 25 30 35 40 45 50 55 65 70 75 80 85 90 95 100 w c THR-30185 efficiency vrs. vin 77.00 77.50 78.00 78.50 79.00 79.50 80.00 80.50 81.00 81.50 82.00 82.50 83.00 83.50 84.00 10.00 12.00 15.00 18.00 24.00 36.00 vin %
|